Sole UK & European Agents
For Showa Centralised
Lubrication Systems

Showa

T: 02476 223 226
    E:

LCB3 Lubrication Unit

– Motorised pump unit for the volumetric type system
– Discharge timer option available (10 settings between 2 to 192 minutes)
– General purpose pump unit

Description

Description

The LCB3 units are fitted with a die-cast aluminium 3.4L tank, cover, and flange. IC timer (control board) fitted units can be adjusted to operate between 2 to 192 minutes.

These units are also fitted with indicator lamps, enabling verification of operational status and errors.
Immediate oil distribution can be initiated manually, by pressing the “Instant Button”.

Form Code

Showa Centralised Lubrication System- Volumetric Motarised Pump Units- LCB3 Lubrication Unit - Form Code

Specification

MODEL
CODE
Pump
Utilized
Intermittence
(YT Timer Option)
Discharge Vol.
(L / minute)
Discharge
Pressure
Tank Capacity
(L)
Effective
Tank
Capacity  (L)
Viscosity
Range
LCB3 MLB01W1 2, 4, 6, 8, 16, 24, 32,
48, 64, 128, 192mins
0.1L – 50Hz
0.12L – 60Hz
1.2MPa 3.4 2 50~800
m㎡/s

lubricant can be discharged by pressing the “Instant button”.   The pump will continue to operate until the button is released.

MOTOR SPECIFICATION

Voltage & Freq. 100V 50Hz 100V 60Hz 200V 50Hz 200V 60Hz
Current (A) 1.5A 1.2A 0.8A 0.6A
Output & Poles 17W × 2P
Operation Max. 5mins with resting time of operation × 2

E – type insulation

Drawing

Showa Centralised Lubrication System- Volumetric Motarised Pump Units- LCB3 Lubrication Unit - Drawing