Description
Description
Utilising an IC timer, the MY6 can be set to discharge oil from a range of selectable interval times. Possessing an “adjustment nut”, the discharge volume per cycle can be set between 1~6c㎥.
The maximum discharge pressure for any discharge volume setting is 0.5MPa.
The MY6 also possesses an “Instant Button”, enabling immediate discharge of oil when required.
Form Code
Specification
MODEL CODE |
Discharge Pressure (MPa) |
Discharge Volume (c㎥/cy) |
Intermittence Times Selectable (mins) |
Outlet Port Size |
Tank Type &Capacity |
Effective Tank Cap. (L) |
Temp. Range(℃) |
Viscosity Range (m㎡/s) |
|
× 1 Setting | × 10 Setting | ||||||||
MY60 | 0.5 Max |
1~6 Adjustable |
2, 4, 6, 8, 10, 12, 14, 16, 18 |
20, 40, 60, 80, 100, 120, 140, 160, 180 |
2 – Rc1/8 (One on each side) |
2L Plast. | 1.3 | -10~+40 | 50~800 |
MY61 | 2L Alumi. | 1.3 | |||||||
MY62 | 4L Plast. | 2.9 |
POWER SPECIFICATION
Power Code | C | B | ||
Phase Motor | 1 | 1 | ||
Voltage (V) | 100 | 200 | ||
Frequency (Hz) | 50 | 60 | 50 | 60 |
Consump. (A) | 1.6 | 1.3 | 0.9 | 0.7 |
Output & Poles | 17W × 2P |