Sole UK & European Agents
For Showa Centralised
Lubrication Systems

Showa

T: 02476 223 226
    E:

YET A2P2 Lubrication Pump

– Lubrication: The lubricator runs via lubrication time after power-on.
– Intermittence: The lubricator runs via intermittent time after power-on.
– Memory: The lubricator runs via the previous set after power-on.

Category:

Description

Description

Lubrication and intermittent time can be adjusted.
The float switch alarms and output signal when the oil level is low.
The pressure release device is included.
The over temperature/load protector is attached to protect the motor.
The function of fixed pressure for the pressure relief valve can prolong the system life
Lubrication time (second/minute) and intermittent time (second/minute/hour/cycle) are adjustable.
The indicator on the panel can display the operation of the lubricator.
The intermittent period can be adjusted via the machine’s action cycles.
Pressure switch is an option for YET-A2P2.
“RES” key can force the lubricator to function.

Specification

Model YET-A2 YET-A2P2
Voltage (Single Phase) 110V or 220V 110V or 220V
Consumption Power (W) 100 100
Capacity of Terminal Output DC/AC 250V 3A DC/AC 250V 3A
Lubrication time (second/minute) 1-999 1-999
Intermittent Time (second/minute/hour/cycle) 1-999 1-999
Output Bore Ø4 or Ø6 Ø4 or Ø6
Max. Output Pressure Mpa (kgf/cm2) 1.5 (15) 1.5 (15)
Output Volume (cc/mm) 150 150
Pressure Release device O O
Float Switch O O
Pressure Switch (kgf/cm2) X 12-9
Pressure Gauge O O
Alarm Beeper O O
Tank Capacity (L) 2 3 4
(Aluminum Tank)
Weight (kg) 2.7 2.9 3.7
Note: Because of continuous improvements, above specifications are subject to change without prior notice.

 

Drawing

Ishan Lubrication - YET A2P2 Lubrication Pump - Drawing